Surface Mount Connector with Wire
When heat penetration testing is conducted on rolling cans in an FMC Steritort, specialized equipment is needed. Circuits and connectors on the Hub installed in the Steritort may need to be replaced. These connectors consist of three components: wire (of specified length), a Surface Mount Connector/Receptacle (#S30) on the hub end, and either a Male Subminiature Connector (#SUBMIN-M) or a raw end (nothing installed) on the CALPlex datalogger end. Each connector is installed into the Hub on a Steritort or into the connection panel inside a pilot retort, and allows for the male locking end of a Rotary Contactor or a Male Thermocouple Connector to connect to it. You can customize your product below.
Steritort Hub
Surface Mount Connectors (S30's) can be installed into the Hub on an FMC Steritort. The hub allows for 18 S30's to be mounted on it. The wires attached to the S30's run through the hub and out the back of the retort, where the Subminiature Connectors plug into the Rotary CALPlex mounted on the retort. Rotary Contactors can connect to the S30's on the hub.
Pilot Retort Panel
Surface Mount Connectors (S30's) can be installed into the connection panel inside a pilot retort. The panel allows for 16 S30's to be mounted on it. The wires attached to the S30's run through the rotor and out the back of the retort, where the Subminiature Connectors plug into the Rotary CALPlex mounted on the retort. Male Thermocouple Connectors can connect to the S30's on the panel.